We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-ARA-AL1A1-M-R-121050
Part number
121050
Description
Safety switch unicode MGB-L1-ARA-AL1A1-M-R-121050
Stock availability:
On request
If you are seeking Euchner MGB-L1-ARA-AL1A1-M-R-121050 121050, catch up with FAMAGA, the world's primary retailer of streamlined equipment. Our company has worked for more than ten years - these are ages of experience, which are illustrated in the quality of items and private attention to each user. We respect everyone, who conspired with us - so, our regular purchasers bring in the most attractive purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such consumers, and we constantly arrange new agreements. More than 700 contracts are concluded per day, because FAMAGA works all over the planet Germany, United Kingdom, Sri Lanka, The Bahamas, Colombia, Hungary, New Zealand, Poland, Togo, Haiti, Malawi, Philippines, Japan, Bangladesh, The Gambia, China, Argentina, Jamaica, Estonia, Fiji, Norway, Eritrea, Nepal, Mauritius, Morocco, Kyrgyzstan, Suriname, Zambia, Serbia, Latvia, Luxembourg, Nigeria, Comoros, Kenya, Croatia, Afghanistan, Cape Verde, Qatar, Eswatini, Finland, Yemen, Djibouti, Dominica, South Korea, Laos, Vietnam, Georgia. A advanced logistics series and a partnership network cheer us to ship our units anywhere in the planet immediately without damaging product quality.
A particular source of repute for FAMAGA is its team members, each of whom contributes to common cause. We propose into our team only specialists, who already have experience in the sphere of manufacturing equipment.
All merchandises from FAMAGA are affirmed - we are responsible for the result of our work. Now, more than 10 million units of products have been supplied, and this amount is ascending every day. We are happy that purchasers choose FAMAGA again and again, and we are glad to make more developed and technologically innovative industrial equipment so as stay in control.
To request or order, phone us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 1 NO contact, illuminated |
S2 | 1 NO contact, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |