Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ8-18GK-N-150
Part number
106466
Type
Inductive sensor
Description
Inductive sensor NJ8-18GK-N-150
Stock availability:
On request
If you are inspecting Pepperl+Fuchs NJ8-18GK-N-150 106466, get in touch with FAMAGA, the world's leading retailer of industrial equipment. Our company has lasted for more than ten years - these are cycles of experience, which are illustrated in the quality of products and individual attention to each consumer. We respect everyone, who cooperated with us - therefore, our regular clients obtain the most flexible purchase forms and discounts on the industrial equipment market. At this time, there are more than 4 thousand such clients, and we constantly compose new agreements. More than 650 proceedings are resolved per day, because FAMAGA works all over the globe Germany, United Kingdom, Honduras, Côte d\'Ivoire, Zambia, Mauritius, Italy, Turkmenistan, Guinea, Brazil, Comoros, Vietnam, Albania, Tajikistan, Grenada, Fiji, Mozambique, Croatia, Switzerland, Equatorial Guinea, Japan, Andorra, Mexico, Mauritania, Uganda, Burkina Faso, Latvia, Cyprus, Burundi, Djibouti, Dominica, Yemen, Sierra Leone, Benin, Bolivia, China, Israel, Philippines, Australia, Indonesia, Nepal, Georgia, Samoa, Sweden, Pakistan. A advanced logistics link and a partnership network let us to conduct our units anywhere in the globe as soon as possible without undermining product quality.
A special source of good name for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only professionals, who already have experience in the range of factory-made equipment.
All merchandises from FAMAGA are ensured - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been supplied, and this number is increasing every day. We are happy that purchasers choose FAMAGA again and again, and we are pleased to make more advanced and technologically modern industrial equipment so as to stay on the top.
To inquire or book, call us by phone or write a message to the online chat on our site. You can also dispatch a list of the desirable equipment to the email of our company - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 8 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 6.48 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 200 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 150 °C (-40 ... 302 °F) | |
Mechanical specifications | ||
Connection type | cable SIHF , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PPS | |
Sensing face | PPS | |
Degree of protection | IP65 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G |